Put Both Labels In Watt Hours

Nominal energy in watt-hours equals nominal volts multiplied by amp-hours. Two batteries marked 100 Ah can store different amounts of energy if their voltages differ. The number at a station’s USB socket or its 120 V AC outlet is an output voltage. Use the battery pack’s rated nominal voltage for a pack calculation. Battle Born battery-bank sizing guide.

Example label conversions
Battery labelNominal energy
12 V × 100 Ah1,200 Wh
12.8 V × 100 Ah1,280 Wh
25.6 V × 50 Ah1,280 Wh

Keep A Reserve And Allow For Conversion

Suppose the 1,280 Wh battery is full and you choose to leave 25% available on return. That leaves a 960 Wh DC budget under this planning assumption. If the AC path delivers 85% of that amount after losses, the example budget is 816 Wh at the appliance. The 25% reserve and 85% allowance are assumptions to replace with battery guidance and observed performance.

Assign Each Load To Its Battery

Four hours at a measured average 120 W uses 480 Wh at the appliance. That fits the example energy budget before other loads. Check the inverter’s output rating separately. If a roof fan remains on the house bank and the laptop plugs into the station, deduct each from its own budget. Add their capacities together only for a system specifically designed to share them.