Write The Battery Name Beside Every Reading
A shunt-based house monitor measures current flowing into and out of its monitored bank. Victron’s SmartShunt reports net current, accumulated amp-hours and estimated state of charge. On that model, negative current means discharge and positive means charge. Consult your own monitor for its sign convention. A station display instead tracks the station’s internal pack and active ports. Victron SmartShunt operating guide.
Make An Overnight Record
Suppose the house monitor shows an average net discharge of 3 A for eight hours while the lights and a cycling fridge use the house bank. That is about 24 Ah, or roughly 307 Wh at a nominal 12.8 V. If a laptop separately uses 120 Wh from the station, record that 120 Wh against the station. The house shunt has no reason to include it.
For the next night, note the time, house charge percentage, consumed Ah and station percentage at bed and breakfast. A momentary current reading when the fridge is idle will understate its average. If solar starts before breakfast, the house change already includes that incoming charge.
Recognize An Unsynchronized Estimate
The SmartShunt shows dashes for state of charge when unsynchronized. Its manual explains how battery capacity settings and charge detection affect the estimate. Use its documented full-charge synchronization procedure for that battery system. If the displayed percentage still disagrees with repeated current and time observations, ask the installer to review the monitor setup before relying on its time-to-go figure. Victron synchronization and time-remaining guidance.