Compare A Flat Surface With A Fixed Tilt

A panel’s tilt is the angle above horizontal. Zero degrees is flat. The federal Solar Resource Data example for 40° N, 105° W compares horizontal radiation with a fixed, equator-facing surface tilted 40°. In January the averages are 2.50 and 4.79 kWh/m²/day, respectively. In June they are 7.25 and 6.47. In that historical example, the tilt helps in January and the flat surface receives more daily energy in June. It compares two positions at one location and cannot identify the best angle at every campsite. Monthly horizontal and latitude-tilt data.

Include The Hours The Stand Can Stay Out

Suppose a steeper, approved stand position averages 155 W for two usable hours before a nearby RV shades it. That yields 310 Wh at the input. A second stable position averages 115 W for four hours and yields 460 Wh. The latter produces 150 Wh more over the stay. These are assumed averages, so use repeated readings or station energy totals to replace them. A midday peak alone cannot do that calculation.

Choose A Practical Ground Setting

Check the stand’s approved positions, ground stability, wind exposure and the sun’s path around nearby vehicles. Leave clear walking space around the panel and lead. Compare candidate angles in similar light with the same station and loads. Use a fixed-array model such as PVWatts to compare the actual angles available for the month of travel, then shorten the collecting window if you will pack up early. PVWatts monthly and hourly results. Roof angle changes and roof work are outside this ground-panel comparison.