Use The Destination And Travel Month
Enter the campsite or a nearby town in PVWatts. For a stationary RV use a fixed array, then enter the tilt and compass direction the panel can actually maintain. Read the monthly solar radiation value in kWh/m²/day. Its number is equivalent to daily peak sun hours for that modeled surface. PVWatts also reports estimated electrical production for the model system. Use the radiation column when multiplying by your own panel watts. How to read PVWatts results.
Compare Two Months At The Same Location
The federal Solar Resource Data example at 40° N, 105° W in Colorado gives a horizontal surface 2.50 kWh/m²/day in January and 7.25 in June. These are historical monthly averages based on 1998–2009 resource data. For a flat 200 W panel, assume 75% of the nameplate-times-sun estimate arrives as useful charging energy, with no significant input clipping. January gives 200 × 2.50 × 0.75 = 375 Wh/day. June gives about 1,088 Wh/day. The 75% figure is a planning assumption, not a measured efficiency for that site. Solar Resource Data example and surface definitions.
Allow For The Campsite You Actually Use
A 600 Wh daily load in that January example leaves a 225 Wh daily shortfall. A sunny first day does not erase it from the rest of the plan. Note local trees, mountains, awnings and the hours a portable panel will be packed away. Avoid subtracting the same shading loss twice. Use the month as a planning baseline and revise the estimate with actual daily recharge readings after arrival.