Use The Furnace’s Electrical Rating

Suburban’s SF-Q listing for item 2552A gives a 20,000 BTU/h input rating alongside 12 V and 5.1 A of electrical draw. For a rough DC running figure, 12 V × 5.1 A = 61.2 W. The BTU number describes fuel input; converting it into watts and treating it as battery draw would budget for the wrong energy source. Other furnaces can draw different current. Suburban SF-Q product specifications.

Compare Two Eight-Hour Nights

Use the manufacturer figure above as the assumed active current and ignore idle draw for this first estimate. Three active hours use 5.1 A × 3 h = 15.3 Ah, about 184 Wh at nominal 12 V. Six active hours use 30.6 Ah, about 367 Wh. The longer night adds roughly 184 Wh of electrical demand even though both nights last eight hours.

Count the time the blower actually operates, including its run after the burner stops. Add any standby use and account for the installed supply path. When using an observed battery-monitor total for the whole night, lights and fans may already be included.

Plan For The Morning After The Coldest Night

Record total active time and outside conditions on a night with a dependable supply. Compare that history with expected trip conditions and the other overnight loads. Check how the installed coach DC system would receive energy from the station with your RV manufacturer or qualified service provider. A station’s household AC rating alone does not establish that it can support the installed furnace.

Budget morning energy before expected solar recovery. Fuel availability, service condition and the RV’s normal heat contingency remain independent of this battery arithmetic.